Identification | | This command echoes back information about the test system. | | Syntax: | IDN<CR> | | | <CR> = carriage return | | | <LF> = line feed | | Example: | IDN<CR> - Returns “JFW Industries, Inc., Model 50PA-374, Firmware Rev A<CR><LF>” | | Notes: | Command is not case sensitive. | | | Command must be terminated by a carriage return. |
|
Read Attenuator | | The read attenuator command returns the attenuation setting for a specific attenuator. | | Syntax: | RAx<CR> | | | x = attenuator number | | | <CR> = carriage return | | | <LF> = line feed | | Example: | SA2 85<CR> - Sets the attenuation of attenuator #2 to 85dB | | | RA2<CR> - Reads attenuator #2 setting and returns “Atten #2 = 85dB<CR><LF>” | | | SA5 0<CR> - Sets the attenuation of attenuator #5 to 0dB | | | RA5<CR> - Reads attenuator #5 setting and returns “Atten #5 = 0dB<CR><LF>” | | Notes: | Command is not case sensitive. | | | Command must be terminated by a carriage return. |
|
Set Attenuator | | The set attenuator command is used to set the attenuation level of a specific attenuator. | | Syntax: | SAx y<CR> | | | x = attenuator number | | | y = attenuation level | | | <CR> = carriage return | Example: | SA1 127<CR> - Sets attenuation of attenuator #1 to 127dB | | | SA12 98<CR> - Sets attenuation of attenuator #12 to 98dB | | Notes: | Command is not case sensitive. | | | Command must be terminated by a carriage return. |
|
Read Switch | | The read switch command returns the port setting for a specific switch. | | Syntax: | RSx<CR> | | x = switch number | | <CR> = carriage return | | <LF> = line feed | | Example: | SS1 8<CR> - Sets switch #1 to port #8 | | RS1<CR> - Reads switch #1 setting and returns “J8<CR><LF>” | | Notes: | Command is not case sensitive. | | Command must be terminated by a carriage return. |
|
Set Switch | | The set switch command is used to set a switch to a specifi c port number. | | Syntax: | SSx y<CR> | | x = switch number | | y = port number | | <CR> = carriage return | | Example: | SS1 8<CR> - Sets switch #1 to port #8 | | SS2 5<CR> - Sets switch #2 to port #5 | | Notes: | Command is not case sensitive. | | Command must be terminated by a carriage return. | | Ethernet and RS-232 Command Information |
|
Read Output | | The read output command is used to see if the output port is connected to any input port. | | Syntax: | ROx<CR> | | x = output port number | | <CR> = carriage return | | <LF> = line feed | | Example: | SO3 1<CR> - Connects output port #3 to input port #1 | | RO3<CR> - Reads output port #3 setting and returns “J1<CR><LF>” | | SO3 0<CR> - Sets output port #3 to unused state | | RO3<CR> - Reads output port #3 setting and returns “J0<CR><LF>” | | Notes: | Command is not case sensitive. | | Command must be terminated by a carriage return. |
|
Set Output | | The set output command is used to set the output port of a matrix switch to a specifi c input port. | | Syntax: | SOx y<CR> | | x = output port number | | y = input port number | | <CR> = carriage return | | Example: | SO3 1<CR> - Connects output port #3 to input port #1 | | SO8 4<CR> - Connects output port #8 to input port #4 | | Notes: | Command is not case sensitive. | | Command must be terminated by a carriage return. |
|
Read Input | | The read input command is used to see if the input port is connected to any input port. | | Syntax: | RIx<CR> | | x = input port number | | <CR> = carriage return | | <LF> = line feed | | Example: | SI3 12<CR> - Connects input port #3 to output port #12 | | RI3<CR> - Reads input port #3 setting and returns “J12<CR><LF>” | | SI3 0<CR> - Sets input port #3 to unused state | | RI3<CR> - Reads output port #3 setting and returns “J0<CR><LF>” | | SI15 7<CR> - Sets input port #15 to output port #7 | | RI15<CR> - Reads output port #15 setting and returns “J7<CR>< LF>” | | Notes: | Command is not case sensitive. | | Command must be terminated by a carriage return. |
|
Set Input | | The set input command is used to set the input port of a matrix switch to a specifi c output port. | | Syntax: | SIx y<CR> | | x = input port number | | y = output port number | | <CR> = carriage return | | Example: | SI1 3<CR> - Connects input port #1 to output port #3 | | SI4 8<CR> - Connects input port #4 to output port #8 | | SI12 1<CR> - Connects input port #12 to output port #1 | | SI12 11<CR> - Connects input port #12 to output port #11 | | Notes: | Command is not case sensitive. | | Command must be terminated by a carriage return. Ethernet and RS-232 Command Information |
|
Fade Attenuator | | This command fades an attenuator from one attenuation setting to another attenuation setting. It is possible to fade attenuation up or down. The interval time can be set in seconds or milliseconds. | | Milliseconds Syntax: | FAx y z tM<CR> | | Seconds Syntax: | FAx y z tS<CR> | | x = attenuator number | | y = starting attenuation setting | | z = ending attenuation setting | | t = interval time (1 through 9999) | | M = sets interval time in milliseconds | | S = set interval time in seconds | | <CR> = carriage return | | Example: | FA1 0 63 300M<CR> | | Fade attenuator #1 from 0dB to 63dB in 1dB steps with 300 milliseconds between steps. | | FA1 63 0 1S<CR> | | Fade attenuator #1 from 63dB to 0dB in 1dB steps with 1 seconds between steps. | | FA12 0 127 50M<CR> | | Fade attenuator #12 from 0dB to 127dB in 1dB steps with 50 milliseconds between steps. | | FA3 127 6 1000M<CR> | | Fade attenuator #3 from 127dB to 6dB in 1dB steps with 1000 milliseconds between steps. | | Notes: | Command is not case sensitive. | | Command must be terminated by a carriage return. Ethernet and RS-232 Command Information |
|
Variable Handover | | This command fades one attenuator up in attenuation while fading a second attenuator down in attenuation. | | Milliseconds Syntax: | VHND Av Aw Vx Vy TzM<CR> | | Seconds Syntax: | VHND Av Aw Vx Vy TzS<CR> | | v = attenuator number to start at low dB value (steps up to high dB value) | | w = attenuator number to start at high dB value (steps down to low dB value) | | x = starting attenuation setting for attenuator “v” | | y = starting attenuation setting for attenuator “w” | | z = interval time (1 through 9999) | | M = sets interval time in milliseconds | | S = set interval time in seconds | | <CR> = carriage return | | Example: | VHND A1 A2 V0 V63 T300M<CR> | | Fades attenuator #1 from 0dB to 63dB in 1dB steps. | | Fades attenuator #2 from 63dB to 0dB in 1dB steps. | | Interval time is 300 milliseconds between steps. | | VHND A8 A15 V7 V127 T2S<CR> | | Fades attenuator #8 from 7dB to 127dB in 1dB steps. | | Fades attenuator #15 from 127dB to 7dB in 1dB steps. | | Interval time is 2 seconds between steps. | | Notes: | Command is not case sensitive. | | Command must be terminated by a carriage return. |
|
Pause | | The pause command pauses the test system from executing any new commands for a specified duration. | | Milliseconds Syntax: | PAUSExM<CR> | | Seconds Syntax: | PAUSExS<CR> | | x = duration of time to pause (1 through 9999) | | M = sets interval time in milliseconds | | S = set interval time in seconds | | <CR> = carriage return | | Example: | PAUSE100M<CR> - Test system pauses for 100 milliseconds | | PAUSE56S<CR> - Test system pauses for 56 seconds | | Notes: | Command is not case sensitive. | | Command must be terminated by a carriage return. | | Script Example: | FA9 5 2 1S<CR> - Fades attenuator #9 from 5dB to 2dB at 1 second/step. | | PAUSE4000M<CR> - Test system pauses for 4 seconds (4000 milliseconds). | | FA9 2 5 1 S<CR> - Fades attenuator #9 from 2dB to 5dB at 1 second/step. |

|
Disconnect Command | | This command causes the test system to close the existing Ethernet connection. This command is only used while in Ethernet mode. This command is useful if you are using a terminal program to control the test system. | | Syntax: | DIS<CR> | | <CR> = carriage return | | Examples: | DIS<CR> | | When the command is received and processed, the Ethernet connection will be closed. | | Notes: | Command is not case sensitive, but must be terminated by a carriage return. Command must be terminated by a carriage return. |
|
Change Baud Rate | | This command is used to change the baud rate of the test system. This command only works in RS-232 mode. | | Syntax: | CBx<CR> | | x = new baud rate | | <CR> = carriage return | | Examples: | Example: CB9600<CR> - Changes the baud rate to 9600 baud | | CB19200<CR> - Changes the baud rate to 19200 baud | | CB38400<CR> - Changes the baud rate to 38400 baud | | Notes: | Command is not case sensitive. | | Command must be terminated by a carriage return. |
|