Handover Test Systems for Cellular Testing
Family of handover test systems designed for handset-to-network handover testing. Internal step attenuators allow the RF signal between the network access points and the handsets to be dynamically faded up/down. The Ethernet/Serial models run our latest generation 3.x.x firmware that features easy to use ASCII formatted commands.
- Full fan-out models provide the greatest testing flexibility with individually controlled step attenuator on every RF path thru the matrix.
- Limited fan-out models use a common highway configuration which reduces the number of internal paths and the number of attenuators.
- Manual handover models use manually controlled attenuators for simple benchtop testing.
- Display 15 Products per page
-
2 x 1 LC Handover Test System 2-6 GHz | 50BA-007-95
JFW Model #: 50BA-007-95
Impedance: 50 Ohms
Configuration: 2 x 1 LC Handover System
dB Total: 95 dB
dB Step: 1 dB
Frequency Start: 2000 MHz
Frequency Stop: 6 GHz
Control: Manual, Ethernet, RS-232
RF Connectors: SMA Female
Documentation: Data Sheet | Drawing -
4 x 4 LC Handover Test System 2-6 GHz | 50PA-561
JFW Model #: 50PA-561
Impedance: 50 Ohms
Configuration: 4 x 4 LC Handover System
dB Total: 63 dB
dB Step: 1 dB
Frequency Start: 2000 MHz
Frequency Stop: 6 GHz
Control: Manual, Ethernet, RS-232
RF Connectors: SMA Female
Documentation: Data Sheet | Drawing -
8 x 8 LC Handover Test System 2-6 GHz | 50PA-688
JFW Model #: 50PA-688
Impedance: 50 Ohms
Configuration: 8 x 8 LC Handover System
dB Total: 95 dB
dB Step: 1 dB
Frequency Start: 2000 MHz
Frequency Stop: 6 GHz
Control: Manual, Ethernet, RS-232
RF Connectors: SMA Female
Documentation: Data Sheet | Diagram | Drawing -
4 x 1 LC Handover Test System 2-6 GHz | 50PA-701
JFW Model #: 50PA-701
Impedance: 50 Ohms
Configuration: 4 x 1 LC Handover System
dB Total: 95 dB
dB Step: 1 dB
Frequency Start: 2000 MHz
Frequency Stop: 6 GHz
Control: Manual, Ethernet, RS-232
RF Connectors: N, SMA Female
Documentation: Data Sheet | Diagram | Drawing -
8 x 2 LC Handover Test System 2-6 GHz | 50PA-716
JFW Model #: 50PA-716
Impedance: 50 Ohms
Configuration: 8 x 2 LC Handover System
dB Total: 95 dB
dB Step: 1 dB
Frequency Start: 2000 MHz
Frequency Stop: 6 GHz
Control: Manual, Ethernet, RS-232
RF Connectors: N, SMA Female
Documentation: Data Sheet | Diagram | Drawing -
16 x 2 LC Handover Test System 2-6 GHz | 50PA-717
JFW Model #: 50PA-717
Impedance: 50 Ohms
Configuration: 16 x 2 LC Handover System
dB Total: 95 dB
dB Step: 1 dB
Frequency Start: 2000 MHz
Frequency Stop: 6 GHz
Control: Manual, Ethernet, RS-232
RF Connectors: N, SMA Female
Documentation: Data Sheet | Diagram | Drawing -
8 x 2 LC Handover Test System 30-3000 MHz | 50PA-811
JFW Model #: 50PA-811
Impedance: 50 Ohms
Configuration: 8 x 2 LC Handover System
dB Total: 95 dB
dB Step: 1 dB
Frequency Start: 30 MHz
Frequency Stop: 3000 MHz
Control: Manual, Ethernet, RS-232
RF Connectors: N, SMA Female
Documentation: Data Sheet | Diagram | Drawing -
Dual 8 x 1 LC Handover Test System 0.7-6 GHz | 50PA-941
JFW Model #: 50PA-941
Impedance: 50 Ohms
Configuration: Dual 8 x 1 LC Handover System
dB Total: 95 dB
dB Step: 1 dB
Frequency Start: 700 MHz
Frequency Stop: 6 GHz
Control: Manual, Ethernet, RS-232
RF Connectors: N, SMA Female
Documentation: Data Sheet | Diagram | Drawing -
16 x 3 LC Handover Test System 0.5-6 GHz | 50PA-951
JFW Model #: 50PA-951
Impedance: 50 Ohms
Configuration: 16 x 3 LC Handover System
dB Total: 95 dB
dB Step: 1 dB
Frequency Start: 500 MHz
Frequency Stop: 6 GHz
Control: Manual, Ethernet, RS-232
RF Connectors: N, SMA Female
Documentation: Data Sheet | Diagram | Drawing -
Quad 8 x 1 LC Handover Test System 0.5-6 GHz | 50PA-962
JFW Model #: 50PA-962
Impedance: 50 Ohms
Configuration: Quad 8 x 1 LC Handover System
dB Total: 95 dB
dB Step: 1 dB
Frequency Start: 500 MHz
Frequency Stop: 6 GHz
Control: Manual, Ethernet, RS-232
RF Connectors: SMA Female
Documentation: Data Sheet | Diagram | Drawing -
Octal 2 x 1 LC Handover Test System 0.7-6 GHz | 50PA-964
JFW Model #: 50PA-964
Impedance: 50 Ohms
Configuration: (8) 2 x 1 LC Handover System
dB Total: 95 dB
dB Step: 1 dB
Frequency Start: 700 MHz
Frequency Stop: 6 GHz
Control: Manual, Ethernet, RS-232
RF Connectors: N, SMA Female
Documentation: Data Sheet | Diagram | Drawing -
8 x 1 LC Handover Test System 0.7-6 GHz | 50PA-978
JFW Model #: 50PA-978
Impedance: 50 Ohms
Configuration: 8 x 1 LC Handover System
dB Total: 95 dB
dB Step: 1 dB
Frequency Start: 700 MHz
Frequency Stop: 6 GHz
Control: Manual, Ethernet, RS-232
RF Connectors: N, SMA Female
Documentation: Data Sheet | Diagram | Drawing -
8 x 2 LC Handover Test System 0.5-6 GHz | 50PA-988
JFW Model #: 50PA-988
Impedance: 50 Ohms
Configuration: 8 x 2 LC Handover System
dB Total: 95 dB
dB Step: 1 dB
Frequency Start: 500 MHz
Frequency Stop: 6 GHz
Control: Manual, Ethernet, RS-232
RF Connectors: N, SMA Female
Documentation: Data Sheet | Diagram | Drawing -
Dual 4 x 1 LC Handover Test System 2-6 GHz | 50PA-1021
JFW Model #: 50PA-1021
Impedance: 50 Ohms
Configuration: Dual 4 x 1 LC Handover System
dB Total: 95 dB
dB Step: 1 dB
Frequency Start: 2000 MHz
Frequency Stop: 6 GHz
Control: Manual, Ethernet, RS-232
RF Connectors: N, SMA Female
Documentation: Data Sheet | Diagram | Drawing -
4 x 1 LC Handover System 800-2700 MHz | 50AA-091
JFW Model #: 50AA-091
Impedance: 50 Ohms
Configuration: 4 x 1 Manual LC Handover System
dB Total: 100 dB
dB Step: 10 dB
Frequency Start: 800 MHz
Frequency Stop: 2700 MHz
RF Connectors: N Female
Documentation: Data Sheet | Drawing