Test Systems
JFW manufactures a variety of RF test systems. We can integrate RF switches, step attenuators, and other various RF components into remotely controlled RF sub systems. For recommendations or a custom model, please email our engineering department directly.
- Attenuator Assemblies: remotely controlled step attenuators
- Handover Test Systems: handset-to-network signal fade testing
- Matrix switches: blocking or non-blocking configurations
- RF Switch Assemblies: remotely controlled RF switches
- Transceiver Test Systems: mesh radio-to-radio signal fade testing
The Ethernet/Serial models run our latest generation 3.x.x firmware that features easy to use ASCII formatted commands.
- Software/Firmware: details and manual for 3.x.x firmware
- Ethernet Test Box: outward facing test box running 3.x.x at fixed IP address 104.63.176.50 (tcp port 3001)
- Sample GUI Programs: example test programs for models running 3.x.x firmware
- Firmware Updates: change log for 3.x.x firmware
- Display 15 Products per page
-
10 x 2 Handover Test System 0.7-6 GHz | 50PA-613
JFW Model #: 50PA-613
Impedance: 50 Ohms
Configuration: 10 x 2 Handover System
dB Total: 95 dB
dB Step: 1 dB
Frequency Start: 700 MHz
Frequency Stop: 6 GHz
Control: Manual, Ethernet, RS-232
RF Connectors: N Female
Documentation: Data Sheet | Diagram | Drawing -
12 Port Transceiver Test System 30-3000 MHz | 50PMA-069
JFW Model #: 50PMA-069
Impedance: 50 Ohms
Configuration: 12 Ports with full mesh fan-out
dB Total: 95 dB
dB Step: 1 dB
Frequency Start: 30 MHz
Frequency Stop: 3000 MHz
Manual Control: Display and Keypad
Remote Control: Ethernet, RS-232
Enclosure Type: 19 inch rack mount
RF Connectors: N, SMA, TNC
Documentation: Data Sheet | Diagram | Drawing -
12 Port Transceiver Test System 350-6000 MHz | 50PMA-155
JFW Model #: 50PMA-155
Impedance: 50 Ohms
Configuration: 12 Ports with full mesh fan-out
dB Total: 95 dB
dB Step: 1 dB
Frequency Start: 350 MHz
Frequency Stop: 6000 MHz
Manual Control: Display and Keypad
Remote Control: Ethernet, RS-232
Enclosure Type: 19 inch rack mount
RF Connectors: N, SMA
Documentation: Data Sheet | Diagram | Drawing -
12 Port/2 RF Hub Radio Test System DC-500 MHz | 50PMA-078
JFW Model #: 50PMA-078
Impedance: 50 Ohms
Configuration: 12 Ports w/ 2 Hubs
dB Total: 127 dB
dB Step: 1 dB
Frequency Start: 0 MHz (DC)
Frequency Stop: 500 MHz
Remote Control: Manual, Ethernet, RS-232
RF Connectors: N, SMA
Documentation: Data Sheet | Diagram | Drawing -
12 x 12 Handover Test System 30-3000 MHz | 50PA-850
JFW Model #: 50PA-850
Impedance: 50 Ohms
Configuration: 12 x 12 Handover System
dB Total: 95 dB
dB Step: 1 dB
Frequency Start: 30 MHz
Frequency Stop: 3000 MHz
Control: Manual, Ethernet, RS-232
RF Connectors: N, SMA, TNC Female
Documentation: Data Sheet | Diagram | Drawing -
16 Port Port LC8 Reduced Mesh Radio Test System 30-3000 MHz | 50PMA-116
JFW Model #: 50PMA-116
Impedance: 50 Ohms
Configuration: 16 Ports LC8
dB Total: 95 dB
dB Step: 1 dB
Frequency Start: 30 MHz
Frequency Stop: 3000 MHz
Remote Control: Ethernet, RS-232
RF Connectors: N, SMA, TNC
Documentation: Data Sheet | Diagram | Chart | Drawing -
16 Port Transceiver Test System 2-6 GHz | 50PMA-070
JFW Model #: 50PMA-070
Impedance: 50 Ohms
Configuration: 16 Ports with full mesh fan-out
dB Total: 95 dB
dB Step: 1 dB
Frequency Start: 2000 MHz
Frequency Stop: 6 GHz
Manual Control: Display and Keypad
Remote Control: Ethernet, RS-232
Enclosure Type: 19 inch rack mount
RF Connectors: N, SMA
Documentation: Data Sheet | Diagram | Drawing -
16 Port Transceiver Test System 30-3000 MHz | 50PMA-055
JFW Model #: 50PMA-055
Impedance: 50 Ohms
Configuration: 16 Ports with full mesh fan-out
dB Total: 95 dB
dB Step: 1 dB
Frequency Start: 30 MHz
Frequency Stop: 3000 MHz
Manual Control: Display and Keypad
Remote Control: Ethernet, RS-232
Enclosure Type: 19 inch rack mount
RF Connectors: N, SMA, TNC
Documentation: Data Sheet | Diagram | Drawing (N) | Drawing (SMA) | Drawing (Optional Castors) -
16 Port/6 RF Hub Radio Test System 30-2000 GHz | 50PMA-099
JFW Model #: 50PMA-099
Impedance: 50 Ohms
Configuration: 16 Ports w/ 6 Hubs
dB Total: 63 dB
dB Step: 1 dB
Frequency Start: 30 MHz
Frequency Stop: 2000 MHz
Remote Control: Manual, Ethernet, RS-232
RF Connectors: SMA
Documentation: Data Sheet | Diagram | Drawing -
16 x 2 LC Handover Test System 2-6 GHz | 50PA-717
JFW Model #: 50PA-717
Impedance: 50 Ohms
Configuration: 16 x 2 LC Handover System
dB Total: 95 dB
dB Step: 1 dB
Frequency Start: 2000 MHz
Frequency Stop: 6 GHz
Control: Manual, Ethernet, RS-232
RF Connectors: N, SMA Female
Documentation: Data Sheet | Diagram | Drawing -
16 x 3 LC Handover Test System 0.5-6 GHz | 50PA-951
JFW Model #: 50PA-951
Impedance: 50 Ohms
Configuration: 16 x 3 LC Handover System
dB Total: 95 dB
dB Step: 1 dB
Frequency Start: 500 MHz
Frequency Stop: 6 GHz
Control: Manual, Ethernet, RS-232
RF Connectors: N, SMA Female
Documentation: Data Sheet | Diagram | Drawing -
2 x 1 LC Handover Test System 2-6 GHz | 50BA-007-95
JFW Model #: 50BA-007-95
Impedance: 50 Ohms
Configuration: 2 x 1 LC Handover System
dB Total: 95 dB
dB Step: 1 dB
Frequency Start: 2000 MHz
Frequency Stop: 6 GHz
Control: Manual, Ethernet, RS-232
RF Connectors: SMA Female
Documentation: Data Sheet | Drawing -
2 x 2 Handover Test System 0.7-6 GHz | 50PA-819
JFW Model #: 50PA-819
Impedance: 50 Ohms
Configuration: 2 x 2 Handover System
dB Total: 63 dB
dB Step: 1 dB
Frequency Start: 700 MHz
Frequency Stop: 6 GHz
Control: Manual, Ethernet, RS-232
RF Connectors: N, SMA Female
Documentation: Data Sheet | Diagram | Drawing -
2 x 3 LC Handover System 800-2700 MHz | 50AA-098
JFW Model #: 50AA-098
Impedance: 50 Ohms
Configuration: 2 x 3 Manual LC Handover System
dB Total: 70 dB
dB Step: 10 dB
Frequency Start: 800 MHz
Frequency Stop: 2700 MHz
RF Connectors: N, SMA Female
Documentation: Data Sheet | Diagram | Drawing -
24 Port Port LC16 Reduced Mesh Radio Test System 30-3000 MHz | 50PMA-109
JFW Model #: 50PMA-109
Impedance: 50 Ohms
Configuration: 24 Ports LC16
dB Total: 95 dB
dB Step: 1 dB
Frequency Start: 30 MHz
Frequency Stop: 3000 MHz
Remote Control: Ethernet, RS-232
RF Connectors: N, SMA, TNC
Documentation: Data Sheet | Diagram | Chart | Drawing