- Display 15 Products per page
-
3 x 8 Handover Test System 0.5-6 GHz | 50PA-836
JFW Model #: 50PA-836
Impedance: 50 Ohms
Configuration: 3 x 8 Handover System
dB Total: 95 dB
dB Step: 1 dB
Frequency Start: 500 MHz
Frequency Stop: 6 GHz
Control: Manual, Ethernet, RS-232
RF Connectors: N, SMA Female
Documentation: Data Sheet | Diagram | Drawing -
32 Port Port LC16 Reduced Mesh Radio Test System 30-3000 MHz | 50PMA-108
JFW Model #: 50PMA-108
Impedance: 50 Ohms
Configuration: 32 Ports LC16
dB Total: 95 dB
dB Step: 1 dB
Frequency Start: 30 MHz
Frequency Stop: 3000 MHz
Remote Control: Ethernet, RS-232
RF Connectors: N, SMA, TNC
Documentation: Data Sheet | Diagram | Chart | Drawing -
32 Port Transceiver Test System 30-3000 MHz | 50PMA-041
JFW Model #: 50PMA-041
Impedance: 50 Ohms
Configuration: 32 Ports with full mesh fan-out
dB Total: 63 dB
dB Step: 1 dB
Frequency Start: 30 MHz
Frequency Stop: 3000 MHz
Manual Control: Display and Keypad
Remote Control: Ethernet, RS-232
Enclosure Type: 27 inch wide rack with castors
RF Connectors: N, SMA, TNC
Documentation: Data Sheet | Diagram | Drawing -
4 Port Transceiver Test System 0.5-6 GHz | 50PMA-083
JFW Model #: 50PMA-083
Impedance: 50 Ohms
Configuration: 4 Ports with full mesh fan-out
dB Total: 95 dB
dB Step: 1 dB
Frequency Start: 500 MHz
Frequency Stop: 6 GHz
Manual Control: Display and Keypad
Remote Control: Ethernet, RS-232
Enclosure Type: 19 inch rack mount
RF Connectors: N, SMA
Documentation: Data Sheet | Diagram | Drawing -
4 Port Transceiver Test System 2-6 GHz | 50PMA-106
JFW Model #: 50PMA-106
Impedance: 50 Ohms
Configuration: 4 Ports with full mesh fan-out
dB Total: 95 dB
dB Step: 1 dB
Frequency Start: 2000 MHz
Frequency Stop: 6 GHz
Manual Control: Display and Keypad
Remote Control: Ethernet, RS-232
Enclosure Type: 19 inch rack mount
RF Connectors: N, SMA, TNC
Documentation: Data Sheet | Diagram | Drawing -
4 Port Transceiver Test System 30-3000 MHz | 50PMA-072
JFW Model #: 50PMA-072
Impedance: 50 Ohms
Configuration: 4 Ports with full mesh fan-out
dB Total: 95 dB
dB Step: 1 dB
Frequency Start: 30 MHz
Frequency Stop: 3000 MHz
Manual Control: Display and Keypad
Remote Control: Ethernet, RS-232
Enclosure Type: Benchtop
RF Connectors: N, SMA
Documentation: Data Sheet | Diagram | Drawing (N) | Drawing (SMA) -
4 Port/1 RF Hub Radio Test System DC-1 GHz | 50PMA-045
JFW Model #: 50PMA-045
Impedance: 50 Ohms
Configuration: 4 Ports w/ 1 Hub
dB Total: 127 dB
dB Step: 1 dB
Frequency Start: 0 MHz (DC)
Frequency Stop: 1000 MHz
Remote Control: Manual, Ethernet, RS-232
RF Connectors: N, SMA
Documentation: Data Sheet | Diagram | Drawing -
4 x 1 LC Handover System 800-2700 MHz | 50AA-091
JFW Model #: 50AA-091
Impedance: 50 Ohms
Configuration: 4 x 1 Manual LC Handover System
dB Total: 100 dB
dB Step: 10 dB
Frequency Start: 800 MHz
Frequency Stop: 2700 MHz
RF Connectors: N Female
Documentation: Data Sheet | Drawing -
4 x 1 LC Handover Test System 2-6 GHz | 50PA-701
JFW Model #: 50PA-701
Impedance: 50 Ohms
Configuration: 4 x 1 LC Handover System
dB Total: 95 dB
dB Step: 1 dB
Frequency Start: 2000 MHz
Frequency Stop: 6 GHz
Control: Manual, Ethernet, RS-232
RF Connectors: N, SMA Female
Documentation: Data Sheet | Diagram | Drawing -
4 x 16 Handover Test System 0.5-6 GHz | 50PA-841
JFW Model #: 50PA-841
Impedance: 50 Ohms
Configuration: 4 x 16 Handover System
dB Total: 95 dB
dB Step: 1 dB
Frequency Start: 500 MHz
Frequency Stop: 6 GHz
Control: Manual, Ethernet, RS-232
RF Connectors: N, SMA Female
Documentation: Data Sheet | Diagram | Drawing (N) | Drawing (SMA) -
4 x 2 Handover Test System 0.5-6 GHz | 50PA-948
JFW Model #: 50PA-948
Impedance: 50 Ohms
Configuration: 4 x 2 Handover System
dB Total: 95 dB
dB Step: 1 dB
Frequency Start: 500 MHz
Frequency Stop: 6 GHz
Control: Manual, Ethernet, RS-232
RF Connectors: N, SMA Female
Documentation: Data Sheet | Diagram | Drawing (N) | Drawing (SMA) -
4 x 4 Handover Test System 0.5-6 GHz | 50PA-947
JFW Model #: 50PA-947
Impedance: 50 Ohms
Configuration: 4 x 4 Handover System
dB Total: 95 dB
dB Step: 1 dB
Frequency Start: 500 MHz
Frequency Stop: 6 GHz
Control: Manual, Ethernet, RS-232
RF Connectors: N, SMA Female
Documentation: Data Sheet | Diagram | Drawing (N) | Drawing (SMA) -
4 x 4 Handover Test System 1-8 GHz | 50PA-1248
JFW Model #: 50PA-1248
Impedance: 50 Ohms
Configuration: 4 x 4 Handover System
dB Total: 70 dB
dB Step: 1 dB
Frequency Start: 1000 MHz
Frequency Stop: 8000 MHz
Manual Control: Display and Keyboard
Remote Control: Ethernet and RS-232
RF Connectors: N, SMA Female
Documentation: Data Sheet | Drawing | Diagram -
4 x 4 Handover Test System 2-6 GHz | 50PA-539
JFW Model #: 50PA-539
Impedance: 50 Ohms
Configuration: 4 x 4 Handover System
dB Total: 95 dB
dB Step: 1 dB
Frequency Start: 2000 MHz
Frequency Stop: 6 GHz
Control: Manual, Ethernet, RS-232
RF Connectors: N, SMA Female
Documentation: Data Sheet | Diagram | Drawing -
4 x 4 Handover Test System 698-3000 MHz | 50PA-1089
JFW Model #: 50PA-1089
Impedance: 50 Ohms
Configuration: 4 x 4 Handover System
dB Total: 127 dB
dB Step: 1 dB
Frequency Start: 698 MHz
Frequency Stop: 3 GHz
Manual Control: Display and Keyboard
Remote Control: Ethernet and RS-232
RF Connectors: N, SMA Female
Documentation: Data Sheet | Drawing | Diagram